Data Acquisition, Signal Conditioning, Recording and Analysis products. Instrumentation, measurement, recording and finally analyzing the results for customers on projects from large structures such as bridges and power pylons through to aircraft structures and jet engines in addition to many different automotive tests.

Data Acquistion M1000 Series Signal Conditioning

Data Acquisition
M1000 Series
Signal Conditioning
Data Acquisition M1500 Series Signal Conditioning System

Data Acquisition
M1500 Series
Signal Conditioning System
Data Acquisition M2000 Series Data Recorders

Data Acquisition
M2000 Series
Data Recorders
Data Acquisition System M4000 Series

Data Acquisition System
M4000 Series
Data Acquisition B+S M3 INTEGRA

Data Acquisition
B+S M3 INTEGRA
Contact Electri-Temp. Corporation

Data Acquisition M1000 Series Signal Conditioning

Number of Channels: 6-(1000-6) or 12-(M1000-12) or 24-(M1000-24)
Signal Inputs: 7 pin lockable DIN. (Other types available to order)
Digital Monitor: Dual range LED display shows channel number, calibration input and voltage output for each channel.
Calibration: ±1mV through ±10V continuously variable (Four switched ranges with fine interpolation control).
Transducer power supply: 3-12 V D.C. in 1V steps. The bridge supply may be de-energised using the On/Off toggle switch.
Output Conditioning (M1000-24 only):
(See Below)
The M1000-24/P has an output conditioning section (accessed by a hinged cover on top of the cabinet, which accepts various post-conditioning cards. e.g. active filters, inteqrators, power amplifiers etc. If this section is not used it is necessary to fit Channel Compensation Cards type M1088-P to route the voltage and current outputs through to the rear panel connectors..
Signal Outputs: Standard: 15 pin 'D' connectors (M1000-6 and M1000-12). 25 pin D’ connector (M1000-24/P) Optional: BNC Special: As required subject to space limitations
Power Supply: 115/230V 45-440Hz by voltage selector on rear panel (Optional 12V.24V D.C.)
Power Consumption: M1000-6 20VA
M1000-12 25VA
M1000-24 30VA
Operating Temperature: 0°C to 40°C
Storage Temperature: - 20°C to +70°C
Dimensions (M1000-6): Height 95mm Width 135mm Depth 245mm .
Weight 2.5kg.
Dimensions (M1000-12): Height 95mm Width 265mm Depth 250mm .
Weight 4kg.
Dimensions (M1000-24): Height 95mm Width 480mm Depth 320mm .
Weight 10kg.
Output Conditioning
The output conditioning section accepts a range of plug-in high level post-conditioning cards. In addition to the standard cards shown below a large library of specials’ has been developed. (Consult factory for details). M1091-01-P Active Filter (Bessel). M1089-P Designer’s card. Ml090-01-P Active Filter (Butterworth). Ml072-P Power Amplifier. Ml092-01-P Active Filter (Tchebyshev). Ml095-P Lineariser. Ml015-P/01 Isolated D.C.transducer excitation supply.

back to top   |    Email Electri-Temp. Corporation

Data Acquisition M1500 Series Signal Conditioning System

4 to 2048 or more Programmable Channels, Computer Controlled

The M1500 is designed for use in high channel count applications to address the need for space conservation and cost effective interfacing with computer based Data Acquisition systems where high sample rates together with hifh accuracy and repeatability are essential.

For fast sampling the system interfaces directtly with the MicroStar range of ISA and PCI data acquisition cards. However, the system architecture also enables easy interfacing with any high performance PC based data acquisition card.The M1500 series housing is a standard Eurocard chassis that accepts up to 16 Signal Conditioner cards giving a total of 64 channel per housing. A MULTIPLEX version is available which uses the Data Acquisition card multiplex control lines thus enabling the acquisition of up to 256 channels into one DA card.The Signal Conditioner cards all have 4 input channels and offer a range of different functions thus enabling the user to "mix and match" transducer and conditioner functionality to suit any particular application. Gain sethngs and zero/cal functions can be set automatically or are fully controllable by the remote computer.Movements can supply a full system integration package, with Signal Conditioning, Computer and bespoke software for the complete solution to your data acquisition requirement. The Signal Conditioning cards can provide for the following sensors: Strain Gauge; Accelerometer; Pressure; Thermocouple; RID; LVDI; Voltage / Current; lOP and Piezo resistive. Specials are available to order.
Brief Specification - Housing
Mechanical: 19" Rack-mount Eurocard open frame chassis
Capacity: 16 card slots (any number up to 16 can be used, providing up to 64 channels)
Supply: ± 15 volts, 1.5 amps (amplifier card supply)
+5 volts, 1.5 amps (logic supply)
+24 volts, 1.5 amps (transducer supply)
Interface: 16 analogue output
4 multiplex control input
1 sample and hold control input
3 digital inputs
RS232C input / output
M1560 - 4 Channel Universal Sensor Amplifier
Sensor / Input Types Jumper selection and input pin connections define type
Strain Gauge / Load Cell Full, 1/2 or 14 Bridge. Bridge completion resistors, jumper selected. ¼ Bridge: 120 ohm, 350 ohm and user defined value, jumper selectable Shunt Cal: Single value, user defined. Activated by RS232 command Absolute zero: shorted input, activated by RS232 command Tare zero / balance: Software controlled ± full-scale output
ICP AC coupled, Low Frequency cut-off: 0.5 Hz Cal: Single value voltage. Activated by RS232 command Absolute zero: shorted input, activated by RS232 command Zero! offset Software controlled ± full-scale output
Piezoresistive Full, 1/2 or 14 Bridge. Bridge completion resistors, jumper selected. ¼ Bridge: 120 ohm, 350 ohm and user defined value, jumper selectable Shunt Cal: Single value, user defined. Activated by RS232 command Absolute zero: shorted input, activated by RS232 command Tare zero / balance: Software controlled ± full-scale output
Voltage / Current DC coupled to ±10 volts Current through user fitted series resistor (max 50mA) Cal: Single value voltage. Activated by RS232 command Absolute zero: shorted input, activated by RS232 command Zero / offset: Software controlled ± full-scale output

back to top   |    Email Electri-Temp. Corporation

Data Acquisition M2000 Series Data Recorders

Specification

Mainframe
Number of Channels: 8 or 16, can be increased by mix of analog and l6ch digital boards.
Recording Technique: Thermal array, direct writing, high resolution black on white permanent record.
Paper Loading: Drop-in roll, no threading.
Paper Size:
(Roll)
M2000 Width up to 216mm (8.5) Length 30m (100’) or 60m (200’)
M2200 Width up to 155mm (6”) Length 40m (130’)
Record Length: Selectable in seven steps from 10cm to continuous.
Chart Speeds: 24 speeds from 0.5mm/hr to l0m/sec in real time and/or storage mode.
Channel Configuration: All channels with full paper width overlap or switch selectable to 4 or 8 parallel tracks.
Bandwidth: DC to 10kHz (Up to 80kHz sampling/channel).
Event Marker: Underscores text for duration of event. Operated from front panel or remote contact closure.
Grid Lines: Selectable from front panel. Off, 1cm grid, 1 cm grid plus 2mm fine grid.
Memory: 128 Kbytes per channel, (12 bit ADC), standard. Extendable to 512 Kbytes.
Trace Viewing: Integral, high resolution LED array provides visual presentation of all channels.
Test Annotation: Time, date, run number etc., automatically printed along paper edge. (Test details can be added via the system computer).
Channel Identification: Channel number printed at regular intervals alongside data.
Memory Contents: Front panel bargraph status indicator.
Dimensions (M2000): Height 177mm (7”). Width 400mm
(15.75”). Depth 460mm (18”). Excluding feet and connectors.
Weight 15kg.
Dimensions (M2200): Height 176mm (7”). Width 280mm
(11”). Depth 350mm (14”). Excluding feet and connectors.
Weight 12kg.
Power Supply: 115/230 volts, 45-440Hz (by voltage selector), plus optional integral inverter for 1 2/24V d.c.
Consumption: 8OVA (M2200-8). 100VA (M2000-16).
Signal Conditioning
Signal Inputs: Any type of transducer plus analog or digital signals from microvolts through to 500V rms.
Digital Monitor: 31/2 digit dual range auto-polarity display for reading channel number, voltage output, calibration input and trace start point.
Transducer Supply: Adjustable in lv steps between 3 and 12V D.C. Max current: 1A.
Calibrator: Continuously variable calibration from ±1.000mV to ±10.OOV by front panel control and digital indicator.
Voltage Outputs: All amplifiers/signal conditioners can have optional voltage outputs via rear mounted connectors to drive tape recorders, oscilloscopes and data acquisition systems.
Transient Capture
Trigger Polarity: Positive, negative or both (Switch selectable).
Trigger Allocation: Single or multi-channel in any mix with visual indication of trigger state on all channels.
Pre-Event: Trigger point can be set at five separate stations by selector switch. (Start, 25%, 50%, 75% or End of record).
Trigger Mode: Manual or alternative automatic monitoring where unattended operation is desirable, (i.e. “baby-sit” mode).
Timebase Expansion: Data can be replayed as captured, or expanded for detailed analysis by a factor of up to 50:1.
OPTIONAL EXTRAS Ruggedised Transit Case 19” Rackmount Adaptor Hand Held Remote
Controller 12/24v D.C. Operation Microlog 2000 Data Acquisition Software

back to top   |    Email Electri-Temp. Corporation

Data Acquisition System M4000 Series

M4000 Data Acqusition System

M4000 is a Acquisition Analysis Recording System develop by Micro Movements based on the integration of three well proven products into a unitary system to give a modern and convenient man/machine interface with established hardware reliability and flexibility.

M4000 brings ether software, computer hardware, signal conditioning, ADC, DAC, Pentium processor, keyboard, mouse and TFT display in a rugged metal housing. The system operates under Windows 95® and uses SnapMaster graphical data acquisition analysis software for data recording, display, analysis , playback and manipulation.

The entire package is simple to use with a standard operating system thus reducing training needs. It is easy to configure to a specific task by a technician and once set, can be used by an operator. The unit can operate in a mobile or fixed installation and accommodates 16 channels of differing sensors.

The signal conditioning modules used are interchangeable with those already in use by many customers in our existing range of M1000 Signal Conditioners and 12/150 Recorders. The Complete System in one box...that’s the M4000, giving comprehensive signal conditioning, recording and analysis under Windows operating environment.

back to top   |    Email Electri-Temp. Corporation

Data Acquisition B+S M3 INTEGRA

B+S M3 INTEGRA

Completely integrated mobile data acquisition system not much bigger than a laptop computer. Typical B+S all-in-one design: No external analog signal conditioning. No third-party software to configure first itself and second the system. No faint display on a fragile laptop. The M3 INTEGRA features typical high quality B+S electronics in a rugged machined all-aluminum housing with an integrated super bright TFT display.

Even though the size is small, the features look like the ones of a much larger system. You can simultaneously record analog data coming from external speed sensors, thermocouples, strain gage based sensors and information gathered from your controller bus such as CAN, SCP, ABS, J1850, or other controllers. The B+S M3 INTEGRA keeps all of this information timesynchronized in memory or on hard disk, so that you can look at the status of your controller bus at the exact moment of an analog event.

Since the heart of the system is a Pentium-Class personal computer, you don't have to transfer your data to another system. There is enough space on the up to two hard disks, enough memory, enough computing power to run your analysis software right on the same system. There are, however, a lot of interfaces allowing you a fast and reliable transfer, be it through media (e.g. a ZIP drive at the parallel port) or using the RJ45 universal twisted pair network interface.

Another feature of the M3 INTEGRA is its expandability. You can buy a basic system now and add modules in the future as your application requires. You can choose from our steadily expanding range of modules.

back to top   |    Email Electri-Temp. Corporation


Data Acquistion | Decade Boxes | Digital Thermometers | Dry Blocks / Furnaces | Electrical Safety - Alphatek | Electrical Safety - Clare | Electrical Safety - Sefelec
Hipot / Dielectric Strength | Insulation Testers | Liquid Baths | Megohmmeters | Microhmmeters | Milliohmmeters | Power Quality | Resistance Standards
T/C Calibrators / Simulators | Temperature Standards | Weights and Balances | Test and Measurement Equipment Site Map

© 2008, Electri-Temp. Corporation, All Rights Reserved

New Hampshire (NH) Website Design Development
Alphatek, ASL, Calibration, Clare, Cropico, Data Acquistion, Decade Boxes, Digital Thermometers, Dry Blocks / Furnaces, Electrical Safety Tester, GMC,
Hipot / Dielectric Strength Testers, Insco, Insulation Testers, Isotech, Liquid Baths, Measurement, Megohmmeters, Microhmmeters, Micro Movements,
Milliohmmeters, Power Quality, Resistance Standards, Seaward, Sefelec, T/C Calibrators / Simulators, Techne, Temperature Standards, Weights and Balances,
Connecticut, Maine, ME, Massachusetts, MA, New England, New Hampshire, NH, Rhode Island, RI, Vermont, VT, United States, U.S., USA
Email Electri-Temp. Corporation Electri-Temp. Corporation Home